-40%

Fluke 1732/EUS Three-Phase Electrical Energy Logger with current probes

$ 1960.45

Availability: 27 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Brand: Fluke
  • Condition: New
  • MPN: 1732/EUS
  • Return shipping will be paid by: Seller

    Description

    Untitled Document
    Fluke 1732/EUS Three-Phase Electrical Energy Logger with current probes
    Model:
    1732/EUS
    | Order No:
    1732/EUS
    Designed to find sources of electrical energy waste, which allows the user to locate when and where energy in your facility is being consumed; from the service entrance to individual circuits. Additionally, the Energy Analyze software package allows users to compare multiple data points over time and comes with current probes.
    Brand:
    Fluke
    Model:
    1732/EUS
    Order No:
    1732/EUS
    Condition:
    NEW
    Description
    Fluke 1732/EUS Three-Phase Electrical Energy Logger with current probes
    Three-phase power measurements made easy
    Deliver easy to use three-phase power measurement data for locating sources of electrical energy waste, overloaded circuits and help users do routine load studies. Find out when and where energy in your facility is being used - from the service entrance to individual circuits. This electrical energy logger is Fluke Connect compatible which allows users to access and share three-phase power data remotely with their team so they can maintain safer working distances and make critical decisions in real-time, minimizing the need for protective equipment, site visits, and check-ins.
    Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.
    Features
    Key measurements: automatically capture and log voltage, current, power, power factor, energy and associated values
    Fluke Connect® compatible: view data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities' WiFi infrastructure
    Convenient instrument powering: power instrument directly from the measured circuit
    Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
    Measure all three phases
    Comprehensive logging: more than 20 separate logging sessions can be stored on the instruments
    Optimized user interface: quick, guided, graphical setup ensures you're capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
    Bright, color touch screen: perform convenient in-the-field analysis and data checks with full graphical display
    Optimized user interface: capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
    Complete "in-the-field" setup through the front panel or Fluke Connect: no need to return to the workshop for download and setup or to take a computer to the electrical panel
    Energy Analyze Plus application software: download and analyze every detail of energy consumption with our automated reporting
    Applications
    Energy studies - full range of electrical power and energy parameters
    Load studies - simple current only logging for load sizing
    General facilities staff
    Facilities engineers
    Building managers concerned with energy costs
    Residential/commercial electricians
    Energy consultants
    Included
    Energy Logger
    Voltage Test Leads
    4 x Alligator Clips
    3 x Flexible Current Probe
    Line Cords
    Carrying Case
    Power Supply
    Color Coding Set
    Specifications
    Voltage
    Range
    1000 V
    Resolution
    0.1 V
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(0.2% + 0.01%)
    Current: Direct Input i17xx-flex 1500 12"
    Range
    150 A
    1500 A
    Resolution
    0.1 A
    1 A
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(1% + 0.02%)
    ±(1% + 0.02%)
    Current: Direct Input i17xx-flex 3000 24"
    Range
    300 A
    3000 A
    Resolution
    1 A
    10 A
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(1% + 0.03%)
    ±(1% + 0.03%)
    Current: Direct Input i17xx-flex 6000 36"
    Range
    600 A
    6000 A
    Resolution
    1 A
    10 A
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(1.5% + 0.03%)
    ±(1.5% + 0.03%)
    Current: Direct Input i40s-EL Clamp
    Range
    4 A
    40 A
    Resolution
    1 mA
    10 mA
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(0.7% + 0.02%)
    ±(0.7% + 0.02%)
    Frequency
    Range
    42.5 to 69 Hz
    Resolution
    0.01 Hz
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(0.1%)
    Auxillary Input
    Range
    ±10 V dc
    Resolution
    0.1 mV
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(0.2% + 0.02%)
    Voltage Min/Max
    Range
    1000 V
    Resolution
    0.1 V
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(1% + 0.1%)
    Current Min/Max
    Range
    Defined by accessory
    Resolution
    Defined by accessory
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±(5% + 0.2%)
    THD on Voltage
    Range
    1000%
    Resolution
    0.1%
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±0.5
    THD on Current
    Range
    1000%
    Resolution
    0.1%
    Intrinsic Accuracy at Reference Conditions
    (% of Reading +% of Full Scale)
    ±0.5
    Power Supply
    Voltage Range
    100 to 500 V using safety plug input when powering from the measurement circuit
    100 to 240 V using standard power cord (IEC 60320 C7)
    Power Consumption
    Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
    Efficiency
    ≥68.2% (in accordance with energy efficiency regulations)
    Maximum No-Load Consumption
    ≤0.3 W only when powered using IEC 60320 input
    Mains Power Frequency
    50/60 Hz ±15%
    Battery
    Li-ion 3.7 V, 9.25 Wh, customer-replaceable
    On-Battery Runtime
    Four hours in standard operating mode, up to 5.5 hours in power saving mode
    Charging Time
    <6 hours
    Data Acquisition
    Resolution
    16-bit synchronous sampling
    Sampling Frequency
    10.24 kHz at 50/60 Hz, synchronized to mains frequency
    Input Signal Frequency
    50/60 Hz (42.5 to 69 Hz)
    Circuit Types
    1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT
    3-φ wye balanced, 3-φ Aron/Blondel (2-element delta)
    3-φ delta open leg, Currents only (load studies)
    Data Storage
    Internal flash memory (not user replaceable)
    Memory Size
    Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
    Basic Interval
    Measured Parameters
    Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
    Averaging Interval
    User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Averaging Time Min/Max Values
    Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
    Demand Interval (Energy Meter Mode)
    Measured Parameters
    Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
    Interval
    User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
    Standards Compliance
    Power
    IEEE 1459
    Interfaces
    USB-A
    File transfer via USB flash drive, firmware updates max. current: 120 mA
    WiFi
    File transfer and remote control via direct connection or WiFi infrastructure
    USB-Mini
    Data download device to PC
    Voltage Inputs
    Number of Inputs
    4 (3 phases and neutral)
    Maximum Input Voltage
    1000 Vrms, CF 1.7
    Input Impedance
    10 MΩ
    Bandwidth (-3 dB)
    42.5 Hz to 3.5 kHz
    Scaling
    1:1 and variable
    Measurement Category
    1000 V CAT III/600 V CAT IV
    Current Inputs
    Number of Inputs
    3, mode selected automatically for attached sensor
    Input Voltage
    Clamp input: 500 mVrms/50 mVrms; CF 2.8
    Rogowski Coil Input
    150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
    Range
    1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12"
    3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24"
    6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36"
    40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
    Bandwidth (-3 dB)
    42.5 Hz to 3.5 kHz
    Scaling
    1:1 and variable
    Auxiliary Inputs
    Number of Inputs
    2
    Input Range
    0 to ±10 V dc, 1reading/s
    Scale Factor
    Format: mx + b (gain and offset) user configurable
    Displayed Units
    User configurable (7 characters, for example, °C, psi, or m/s)
    Wireless Connection
    Number of Inputs
    2
    Supported Modules
    Fluke Connect® 3000 series
    Acquisition
    1 reading/s
    Environmental Specifications
    Operating Temperature
    14 to 122 °F (-10 to 50°C)
    Storage Temperature
    -4 to 140°F (-20 to 60°C)
    With battery: -4 to 122 °F (-20 to 50°C)
    Operating Humidity
    50 to 86°F (10 to 30°C) max. 95% RH
    86 to 104°F (30 to 40°C) max. 75% RH
    104 to 122°F (40 to 50 °C) max. 45% RH
    Operating Altitude
    6561.7' (2000 m) [up to 13,123.4' (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV]
    Storage Altitude
    39,370' (12,000 m)
    Enclosure
    IP50 in accordance with EN60529
    Vibration
    MIL-T-28800E, Type 3, Class III, Style B
    Safety
    IEC 61010-1
    IEC Mains Input: Overvoltage Category II, Pollution Degree 2
    Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
    IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
    Electromagnetic Compatibility
    EN 61326-1: Industrial CISPR 11: Group 1, Class A
    Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
    Temperature Coefficient
    0.1 x accuracy specification/°C
    General Specifications
    Color LCD Display
    4.3" (109 mm) active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
    Dimensions
    Instrument: 7.8 x 6.6 x 2.2" (198 x 167 x 55 mm)
    Power supply: 5.1 x 5.1 x 1.8" (130 x 130 x 45 mm)
    Instrument with power supply attached: 7.8 x 6.6 x 3.5" (198 x 167 x 0.9 mm)
    Weight
    Instrument: 2.5 lbs (1.1 kg)
    Power supply: 0.9 lb (400 g)
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.